Type some words to find content.
eg: fuse, arrestor, 00110115 technical, MCCB...
Recent searches
Tehnical support
This email address is being protected from spambots. You need JavaScript enabled to view it.
Filter type
Clear all
Expand all
Open all
39
Size
20
9
4
6
Rated current (A)
1
3
3
3
3
3
3
3
2
2
3
3
1
3
1
2
39
Characteristics
33
6

Charger fuse NH

Items: 0 New items: 39
004110809
New
NHU01XL/150 aR 50A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
280
Power dissipation (0,7x In) (W):
8
004110810
New
NHU01XL/150 aR 63A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
500
Power dissipation (0,7x In) (W):
9
004110811
New
NHU01XL/150 aR 80A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
770
Power dissipation (0,7x In) (W):
13
004110812
New
NHU01XL/150 aR 100A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
2.000
Power dissipation (0,7x In) (W):
10
004110813
New
NHU01XL/150 aR 125A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
3.300
Power dissipation (0,7x In) (W):
12
004110814
New
NHU01XL/150 aR 160A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
5.800
Power dissipation (0,7x In) (W):
15
004110815
New
NHU01XL/150 aR 200A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
10.500
Power dissipation (0,7x In) (W):
18
004110816
New
NHU01XL/150 aR 250A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
16.200
Power dissipation (0,7x In) (W):
23
004110817
New
NHU01XL/150 aR 300A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
22.000
Power dissipation (0,7x In) (W):
28
004110840
New
NHU1/110 aR 63A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
200
Power dissipation (0,7x In) (W):
5,5
004110841
New
NHU1/110 aR 80A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
300
Power dissipation (0,7x In) (W):
6,9
004110842
New
NHU1/110 aR 100A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
500
Power dissipation (0,7x In) (W):
9,2
004110843
New
NHU1/110 aR 125A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
1.000
Power dissipation (0,7x In) (W):
10,8
004110844
New
NHU1/110 aR 160A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
2.000
Power dissipation (0,7x In) (W):
14,9
004110845
New
NHU1/110 aR 200A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
4.000
Power dissipation (0,7x In) (W):
16,7
004110846
New
NHU1/110 aR 250A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
9.000
Power dissipation (0,7x In) (W):
21
004110847
New
NHU1/110 aR 315A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
16.000
Power dissipation (0,7x In) (W):
25,8
004110848
New
NHU1/110 aR 350A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
23.500
Power dissipation (0,7x In) (W):
25,2
004110849
New
NHU1/110 aR 400A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
31.000
Power dissipation (0,7x In) (W):
28,8
004110860
New
NHU1/110/M aR 63A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
200
Power dissipation (0,7x In) (W):
5,5
004110861
New
NHU1/110/M aR 80A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
300
Power dissipation (0,7x In) (W):
6,9
004110862
New
NHU1/110/M aR 100A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
500
Power dissipation (0,7x In) (W):
9,2
004110863
New
NHU1/110/M aR 125A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
1.000
Power dissipation (0,7x In) (W):
10,8
004110864
New
NHU1/110/M aR 160A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
2.000
Power dissipation (0,7x In) (W):
14,9
004110865
New
NHU1/110/M aR 200A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
4.000
Power dissipation (0,7x In) (W):
16,7
004110866
New
NHU1/110/M aR 250A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
9.000
Power dissipation (0,7x In) (W):
21
004110867
New
NHU1/110/M aR 315A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
16.000
Power dissipation (0,7x In) (W):
25,8
004110868
New
NHU1/110/M aR 350A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
23.500
Power dissipation (0,7x In) (W):
25,2
004110869
New
NHU1/110/M aR 400A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
31.000
Power dissipation (0,7x In) (W):
28,8
004110880
New
NHU3/110 aR 500A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
50.000
Power dissipation (0,7x In) (W):
37,4
004110881
New
NHU3/110 aR 630A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
89.000
Power dissipation (0,7x In) (W):
48,5
004110890
New
NHU3/110/M aR 500A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
50.000
Power dissipation (0,7x In) (W):
37,4
004110891
New
NHU3/110/M aR 630A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-4
Prearcing joule integral (A2s):
89.000
Power dissipation (0,7x In) (W):
48,5
004110800
New
NHU3L/150 gPV 300A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-6
Prearcing joule integral (A2s):
30.500
Power dissipation (0,7x In) (W):
19
004110801
New
NHU3L/150 gPV 350A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-6
Prearcing joule integral (A2s):
48.000
Power dissipation (0,7x In) (W):
22
004110802
New
NHU3L/150 gPV 400A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-6
Prearcing joule integral (A2s):
65.300
Power dissipation (0,7x In) (W):
24
004110803
New
NHU3L/150 gPV 450A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-6
Prearcing joule integral (A2s):
89.000
Power dissipation (0,7x In) (W):
26
004110804
New
NHU3L/150 gPV 500A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-6
Prearcing joule integral (A2s):
120.000
Power dissipation (0,7x In) (W):
29
004110805
New
NHU3L/150 gPV 600A/1000V DC
Class name:
Fuse link
Application:
For protection on DC side of EV chargers
Standards:
IEC 60269-6
Prearcing joule integral (A2s):
350.000
Power dissipation (0,7x In) (W):
32
>
>
0
Your basket is empty.